Skip to content

Top 15 PCB Requirements in medical devices (Recommend)

Printed circuit boards (PCBs) are critical components enabling the functionality of medical devices like patient monitors, imaging systems, diagnostics equipment, and therapeutic devices.

The PCBs in medical equipment have stringent design, performance, quality, and regulatory requirements to ensure patient safety and reliability. This article outlines the key considerations for medical PCBs across electrical, mechanical, manufacturing, and regulatory factors.

Electrical Design Requirements

Medical devices impose demanding electrical requirements on PCB design.

1. Low Leakage, Low Noise

Medical signals require amplification and processing of very low voltages down to microvolt levels. This mandates:

  • Minimizing leakage currents in bias circuits
  • Preventing digital switching noise in analog areas
  • Careful stackup and layout for signal integrity
  • Proper grounding, filtering, and shielding

Even small amounts of noise or interference can corrupt tiny physiological signals or sensor outputs.

2. Isolation and Safety

Patient contact circuits need high levels of isolation from line voltages to prevent any electrical hazard shock risks. Key measures include:

  • Reinforced isolation barriers and creepage distances
  • Opto-isolators for signals crossing isolation zones
  • Split power supplies to maintain isolation
  • Proper dielectric spacing in PCB stackup
  • UL, IEC safety certifications for components and materials

3. EMI and ESD Control

The EMI emissions and immunity levels are tightly regulated for medical equipment, requiring:

  • Low-noise components like crystal oscillators
  • Board-level shielding of circuits
  • Careful component placement and routing
  • Liberally used filtering and protection

Robust ESD protection also prevents damage to sensitive inputs.

4. Component Derating

Components must be operated well below rated voltages and temperatures to improve long-term reliability. Key practices:

  • Derating voltages by 20% or more
  • Limiting power dissipation to 50% or less of max ratings
  • Using larger package sizes than electrical need
  • Providing design margin in clock speeds and duty cycles
  • Sufficient cooling for heat-generating components

Mechanical Design Requirements

Medical Devices pcb
Medical Devices pcb

Medical PCBs must withstand constant use in demanding mechanical environments.

5. Vibration and Shock Resistance

Equipment vibration from fans, pumps, and transportation along with occasional shocks require:

  • Interposers, frame mounts, and fasteners to strengthen solder joints
  • Conformal coating to prevent surface mount cracks
  • Avoiding heavy connectors and components in shock-prone locations
  • Careful use of stiffeners, brackets, or backplanes
  • Analysis of resonance frequencies and modes

6. Durability and MTBF

Medical products demand high mean time between failures (MTBF) exceeding 20000 hours. Durability requires:

  • Component derating as mentioned
  • FEA analysis to avoid mechanical weaknesses
  • HAST, temp cycling, drop testing to verify robustness
  • Avoiding BGAs and other fragile packages
  • Conformal coating, potting, or encapsulation
  • Statistical analysis of failure rates

7. Thermal Management

Sustained reliable operation requires preventing overheating through:

  • Generous ground planes and thermal vias
  • High thermal conductivity substrates
  • Heat sinks, fans, and airflow pathways
  • Thermal modeling to identify hot spots
  • Temperature monitoring circuitry
  • Screening components for desired temperature grade

Manufacturing Requirements

Medical PCBs demand tightly controlled manufacturing and inspection.

8. Biocompatibility

All materials must be biocompatible for any patient contact, including:

  • Substrate laminates
  • Solder masks, finishes, and adhesives
  • Component lead materials

Common biocompatible options are FR4, immersion silver coating, and nickle-free solder.

9. Cleanliness

Stringent cleanliness prevents contamination that can impact performance. Requirements:

  • Assembly in ISO Class 7 or better cleanrooms
  • Solvent cleaning of boards and components
  • Laminar airflow assembly stations
  • Package singulation outside cleanrooms
  • Prevention of human contact with assembly materials

10. Traceability

Full traceability for the life of the product enables tracking all materials, components, manufacturing details, inspection results and repairs, supported by:

  • Serialization marking on boards
  • Raw material and component lot/batch tracking
  • Comprehensive data collection and ERP systems
  • Labeling and scanning procedures
  • Detailed equipment maintenance logs

Traceability facilitates root cause analysis and containment in the field.

11. Testing and Inspection

Extensive testing to specifications and standards ensures reliability:

  • Repeated electrical testing under temperature cycling
  • X-ray inspection of internal features like vias
  • Automated optical inspection (AOI) for assembly flaws
  • Solder joint inspection – 2D and 3D scanning
  • In-circuit testing (ICT) for shorts, opens, values
  • Functional testing under use-case scenarios

12. Change Management and Control

Engineering change control processes manage revisions to:

  • Confirm continued compliance with requirements
  • Full regression testing for affected parameters
  • Prototyping to validate changes
  • Gaining regulatory re-approval as needed

Regulatory Requirements

medical-pcb

Medical devices sold worldwide must satisfy different country regulations.

13. UL and IEC 60601 Certification

These overlapping standards establish safety criteria like:

  • Leakage current limits
  • Dielectric voltage withstand
  • Fault tolerance
  • Component spacing/creepage
  • Protective earth/grounding
  • Enclosure ingress protection ratings
  • Marking and labeling

Certification demonstrates compliance to reduce risk.

14. FDA and CE Approval

Regulatory approval is required to market and sell devices. Key steps are:

FDA

  • Device classification
  • Premarket notification 510(k)
  • Submission of testing and design data

CE Marking

  • Conformity assessment
  • Technical file and risk management documentation
  • Review by Notified Body
  • Declaration of Conformity

Re-approval is needed for significant changes.

15. ISO 13485 Quality Management

Implementing ISO 13485 ensures continuous quality:

  • Infrastructure – cleanrooms, ESD control, utilities
  • Process controls – SOPs, ECOs, supplier management
  • Training records
  • Traceability and document control
  • Risk management procedures
  • Quality auditing

Robust certified quality systems satisfy regulators and improve outcomes.

In summary, designing and manufacturing PCBs for medical applications demands rigorous attention across electrical, mechanical, thermal, cleanliness, reliability, traceability, testing, and regulatory factors to achieve safe and effective performance.

Best Practices for Medical PCB Development

medical pcb assembly
medical pcb assembly

Follow these best practices when developing PCBs for medical devices:

  • Maintain superb EMI/EMC and signal integrity through careful stackup design, routing, filtering, and shielding.
  • Incorporate extensive safety measures for electrical isolation and biocompatibility of materials.
  • Perform thorough thermal analysis and heat sinking to dissipate heat from components.
  • Utilize advanced modeling, simulation, and analysis techniques to validate the design.
  • Subject prototypes to aggressive testing under voltage, temperature, vibration, and longevity scenarios.
  • Employ stringent manufacturing and inspection controls for cleanliness, process variability, soldering, etc.
  • Maintain excellent traceability and change control throughout the product lifecycle.
  • Rigorously satisfy all pertinent regulatory, safety, and compliance standards.
  • Utilize certified quality systems and proven program management methodology.
  • Partner with experienced, proven suppliers and engineering teams knowledgeable in medical requirements.

Conclusion

Medical PCBs call for a diligent design approach covering electrical, mechanical, manufacturing, and regulatory factors critical for product efficacy and safety in sensitive life-critical applications.

Careful management of noise, isolation, materials, reliability, inspection, traceability, and compliance ultimately provides peace of mind that patients are protected from harm.

With sound engineering discipline, regulation, and quality systems implementation, PCBs can be successfully developed to enable breakthrough medical advancements.

Frequently Asked Questions

Q: What are some good substrate choices for medical PCBs?

Some commonly used substrates include:

  • FR4 – Cost-effective, can achieve UL94 V-0 flammability rating
  • PTFE/ceramic filled – Increased thermal performance
  • Hydrocarbon ceramic – Superior high frequency properties
  • Polyimide – Excellent thermal shock resistance
  • Rogers laminates – Tight dielectric constant and loss control

Isola, Arlon, and Park/Nelco are leading medical material suppliers.

Q: How can medical equipment achieve immunity to ESD?

Typical ESD protection measures:

  • TVS diodes across I/O signals
  • High pass filtering to attenuate ESD transients
  • Series resistors to limit energy entering board
  • Shielding of exposed connectors and cables
  • ESD coatings like zinc whiskers
  • Antistatic materials and grounding

Q: What are important considerations for PCBs going in portable medical devices?

For portable designs:

  • Withstand shock from drops and impacts
  • Minimize electromagnetic emissions for compliance
  • Handle widely varying thermal conditions
  • Optimize power consumption for battery life
  • Prevent external contaminants like dust and moisture
  • Accommodate battery interfaces and charging circuitry

Q: What are some key standards applicable to medical PCBs?

Relevant standards bodies:

  • UL – UL60601-1, flammability ratings
  • IEC – IEC60601-1, general safety
  • ISO – ISO13485, quality management
  • FCC – EMI emissions limits
  • AAMI – Association for the Advancement of Medical Instrumentation

Q: How can change management help with medical PCB updates?

Effective change management:

  • Reduces inadvertent introduction of faults
  • Maintains traceability between revisions
  • Forces proper failure analysis before changes
  • Ensures extensive re-verification after changes
  • Provides documentation for regulators on changes
  • Prevents unwanted cost and timeline impacts

 

 

 

                Get Fast Quote Now